◎阻火呼吸人孔(GYXA500 600型) 呼吸人孔、防爆阻火呼吸人孔
GYXA500 600 Type Fire retardant breathing hole
阻火呼吸人孔是我廠根據市場需求,參考了*技術資料研制而成的產品。是安裝在石油、化工等物料儲罐頂上的安全應急的通風裝置。通常與阻火呼吸閥配套使用,既能避免因意外原因造成罐內急劇超壓或真空時,損壞儲罐而發(fā)生的事故;又能起到安全阻火的作用。是目前國內保護儲罐安全的理。
產品采用全天候密封結構,以配重來調節(jié)吸入閥瓣和泄壓蓋的開啟,以不銹鋼波紋帶為阻火層來阻止火焰的通過,并設雙抽屜口為清洗更換阻火層提供了方便,縮短了時間??傊?,該產品具有定壓排放、定壓吸入、開閉靈活、安全阻火、結構緊湊、安全可靠等優(yōu)點。
Resistance fire breathing manhole is my factory according to the market demand,refer to the domestic and international advanced technology material developed by the patent products.ls installed in oil and chemical material storage tanks at the top of the safety emergency. Ventilation device,usually with resistance fire breathing valve supporting the use,can avoid the accident reason is caused a sharp overpressure or tank vacuum,damaged tank and accident;and can have safe fire resistance use ls the present domestic protect the safety of the storage tanks ideal device,the product has filled the gap in china.
Product USES all-weather sealing structure,with counterweight to adjust the in halation valve disc and discharge gland open/close to stainless steel corrugated band for the fireproof layer,to prevent the flame through,and a double drawer mouth,relace the fireproof layer for cleaning offer a convenient,shorten the time.all in all,this product has the constant pressure emissions,the constant pressure in haled,flexible,open and close the security fire resistance,compact structure,sealed performance is good,ann all reliable,etc.
◎技術性能 Technical performance
1、操作壓力:正壓:+1765pa(180mmH2O)負壓:-392pa(-40mmH2O)
2、阻火等級:BS 5501:II*標準
3、使用溫度:+60OC~-30OC
4、適用范圍:特別適用于貯存物料以氦氣封頂的拱頂常壓罐。
◎產品結構 Product structure
在阻火呼吸閥正常工作情況下阻火呼吸人孔基本保持密封狀態(tài),儲罐處于正常壓力。當呼吸閥正常工作滿足不了因意外原因造成儲罐壓力急劇超壓時,呼吸人孔的泄壓蓋自動頂開,進行緊急泄壓,使罐內壓力保持正常;當罐內壓力減壓或超真空時,吸入閥便開啟急劇吸入大氣,維護罐內正常壓力;當吸入大氣帶有火花、火焰時,阻火層起到“器壁效應”作用來阻止火焰的通過,以保護儲罐的安全。
In the normal breathing fire resistance work situation,resistance fire breathing manhole basic keep seal state,a tank under normal pressure.when the breathing valve normal work can't satisfy the accident reason is caused because of the store pressure tank sharp pressure,breathing manhole cover pressure relief automatic top open,make emergency pressure relief,that tank to keep normal pressure;when pressure tank or the vacuum pressure sharply,the suction valve and opened ln haled sharply atmosphere,maintain normal pressure tank;when in haled air with fire,fire,fire resistance of a to the wall effect action to prevent the fire in through the,in order to protect the safety of the storage tanks.
◎數據表 Data Sheet